光ケーブル

Copper Patch Cord

Features

  • Snagless, molded boots provide strain relief and prevent kinking as well as snagless cable mining.
  • All Cat5e cables tested to 350MHz; Cat6 cables tested to 250MHz.
  • All have 4-pair, 24 AWG construction with RJ-45 connectors.
  • Available in both straight or crossover pinning.

 

 

 

 

 

 

 

Specifications

Electrical Characteristics
• Conductor DC Resistance - 89Ω/km (maximum)
• Insulation Resistance - 100Ω/km (maximum)
• Dielectric Strength - 500MV/m
• Certification: TIA/EIA

Physical Characteristics
• Wiring Scheme - TSB 568B (AT&T 258A)
• Approvals - RoHS Compliant
• Package Type - Polybag

Conductor (Qty. 4 twisted pair)
• Conductor Type - 24AWG (7/0.20), Stranded Bare Copper
• Insulation - H-D PE
• Diameter - 0.95 ± 0.02mm
• Colors - Blue, Blue-White, Orange, Orange-White, Green, Green-White, Brown, Brown-White

Connector Type (Qty. 2)
• Connector Type - 8P8C (RJ45)
• Gender - Male
• Connector Material - Polycarbonate
• Contact Material - Copper Alloy, Gold Plating - 50µm
• Hood Material - Moulded PVC

Overall Cable
• Jacket - FR-PVC
• Minimum Average Thickness - 0.55mm
• Outer Diameter - 5.30 ± 0.15mm

Product Uses
• 1000 BASE-T; 100 BASE-T; 10 BASE-T (IEEE 802.3)
• 4/16 Mbps Token Ring (IEEE 802.5); 100 VG-AnyLAN
• 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM

 

Ordering Information

o i ds

Download

Download

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets, Via any of these 3 method.

CONTACT US: +65 61003375

EMAIL:sup

CUSTOMER PORTAL

 

Duplex Single Mode Patch Cord

Features

  • • Different type of terminations SC to ST, LC to FC, etc.
  • • ANSI/TIA/EIA-568.B.3 compliant
  • • 50/125µm, 62.5/125µm Multimode Riser
  • • 1.6mm, 2mm, and 3mm Simplex / Duplex
  • • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • • Electric interference immune
  • • Fibers offers low insertion loss once joined to connector
  • • Telcordia GR-326 tested
  • • Lab connectorized, each jumpers includes a quality certificate to state measuring standards
 

Specifications

  • • Maximum Connector Loss: 0.50 dB
  • • Typical Connector Loss: 0.30 dB
  • • Typical Return Loss: -55 dB
  • • Buffer Material: PVC
  • • Buffer OD: 900 µm
  • • Jacket Material: PVC (OFNR riser-rated)
  • • Jacket OD: 1.8 mm
  • • Installation Tensile Load: 100 N (445 lbs)
  • • Long-Term Tensile Load: 50 N (222 lbs)
  • • Maximum Tensile Load: 100 N/cm
  • • Installation (Loaded) Minimum Bend Radius: 5.0cm (1.97in)
  • • Long-Term (Unloaded) Minimum Bend Radius: 3.0cm (1.2in)
  • • Crush Resistance: 750 N/cm
  • • Impact Resistance: 1,000 cycles
  • • Flex Resistance: 5,000 cycles
  • • Attenuation at 1550 nm: 0.25 dB/km
  • • Attenuation at 1310 nm: 0.35 dB/km
  • • Operating Temperature: -20°C to +70°C

Ordering Information

o i ds

Download

Download

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets, Via any of these 3 method.

CONTACT US: +65 61003375

EMAIL:sup

CUSTOMER PORTAL

 

 

MPO Cable

Features

  • • MPO / MTP connector interface patch cord
  • • Customizable fiber optic cable length
  • • Available in 12 and 24 core cable fiber types
  • • Uses multi-mode 50/125um, OM3 /OM4 Bend-insensitive fiber or single-mode (G652D, G657A1) Bend-insensitive fiber types with type 2mm diameter
  • • Comply with IEC 61754-7, Telcordia GR-1435-CORE
  • • RoHS 6 compliant(lead free)
  • • Supports applications such as 40G LAN, 100G LAN or OTU4 100Gbps

 

 

 

 

Specifications

  • • Cable type: 3.2 mm round LSZH jacketed cable
  • • Bandwidth fiber: Multimode OM3 XG lazer optimized ≥2000MHzxKm @850nm
  • • Single Mode OS2 ITU-T G.652d 9micron
  • • Connector-Type: High connectivity MPO
  • • Connector Interface: MPO interface requirements: IEC61754-4.20 and IEC61754-7
  • • Connector End face: MPO end face geometry requirements: EN50377-15-1
  • • Polishing Quality: Polished end-face quality: IEC61300-3-35
  • • Insertion Loss: ≤ 0.5dB OM3 / ≤ 0.6dB SM OS2
  • • Return Loss: ≥ 25dB OM3; ≥ 35dB

Ordering Information

o mp

 

Download

Download

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets, Via any of these 3 method.

CONTACT US: +65 61003375

EMAIL:sup

CUSTOMER PORTAL

 

 

 

Duplex Multimode Patch Cord

Features

  • • Different type of terminations SC to ST, LC to FC, etc.
  • • ANSI/TIA/EIA-568.B.3 compliant
  • • 50/125µm, 62.5/125µm Multimode Riser
  • • 1.6mm, 2mm, and 3mm Simplex / Duplex
  • • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • • Electric interference immune
  • • Fibers offers low insertion loss once joined to connector
  • • Telcordia GR-326 tested
  • • Lab connectorized, each jumpers includes a quality certificate to state measuring standards
 

Specifications

  • • SC Connector Dimensions: 10.6mm Height x 26mm Width x 58mm Depth (with installed duplex clip)
  • • Maximum Connector Loss: 0.50 dB
  • • Typical Connector Loss: 0.30 dB
  • • Typical Return Loss: -25 dB
  • • Buffer Material: PVC
  • • Buffer OD: 900 µm
  • • Jacket Material: PVC (OFNR riser-rated)
  • • Jacket OD: 2.8 mm
  • • Installation Tensile Load: 100 N (445 lbs)
  • • Long-Term Tensile Load: 50 N (222 lbs)
  • • Maximum Tensile Load: 100 N/cm
  • • Installation (Loaded) Minimum Bend Radius: 5.0cm (1.97in)
  • • Long-Term (Unloaded) Minimum Bend Radius: 3.0cm (1.2in)
  • • Crush Resistance: 750 N/cm
  • • Impact Resistance: 1,000 cycles
  • • Flex Resistance: 5,000 cycles
  • • Attenuation at 1300 nm: 1.0 dB/km
  • • Attenuation at 850 nm: 3.5 dB/km
  • • Operating Temperature: -20°C to +70°C

Ordering Information

o i dm

Download

Download

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets, Via any of these 3 method.

CONTACT US: +65 61003375

EMAIL:sup

CUSTOMER PORTAL

 

Simplex Single Mode Patch Cord

Features

  • • The Single Mode Jumper construction is designed to support tough usage, high performance interconnections, easy installation, and saving time
  • • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • • 9/125µm Single Mode that offers a great wide broadband
  • • Telcordia GR-326 and IEEE 802.3u/802.3x/802.3z/802.3j standards tested
  • • 9/125µm Single Mode Riser
  • • 1.6mm, 2mm, and 3mm Simplex / Duplex
  • • Fibers offers low insertion loss once joined to connector
  • • Different type of terminations SC to ST, LC to FC, etc.
 

Specifications

  • • Maximum Connector Loss: 0.50 dB
  • • Typical Connector Loss: 0.30 dB
  • • Typical Return Loss: -55 dB
  • • Buffer Material: PVC
  • • Buffer OD: 900 µm
  • • Jacket Material: PVC (OFNR riser-rated)
  • • Jacket OD: 1.8 mm
  • • Installation Tensile Load: 100 N (445 lbs)
  • • Long-Term Tensile Load: 50 N (222 lbs)
  • • Maximum Tensile Load: 100 N/cm
  • • Installation (Loaded) Minimum Bend Radius: 5.0cm (1.97in)
  • • Long-Term (Unloaded) Minimum Bend Radius: 3.0cm (1.2in)
  • • Crush Resistance: 750 N/cm
  • • Impact Resistance: 1,000 cycles
  • • Flex Resistance: 5,000 cycles
  • • Attenuation at 1550 nm: 0.25 dB/km
  • • Attenuation at 1310 nm: 0.35 dB/km
  • • Operating Temperature: -20°C to +70°C

Ordering Information

o cp

Download

Download

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets, Via any of these 3 method.

CONTACT US: +65 61003375

EMAIL:sup

CUSTOMER PORTAL

 

 

 

Simplex Multimode Patch Cord

Features

  • • Different type of terminations SC to ST, LC to FC, etc.
  • • ANSI/TIA/EIA-568.B.3 compliant
  • • 50/125µm, 62.5/125µm Multimode Riser
  • • 1.6mm, 2mm, and 3mm Simplex / Duplex
  • • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • • Electric interference immune
  • • Fibers offers low insertion loss once joined to connector
  • • Telcordia GR-326 tested
  • • Lab connectorized, each jumpers includes a quality certificate
  • • to state measuring standards
 

Specifications

  • • Maximum Connector Loss: 0.50 dB
  • • Typical Connector Loss: 0.30 dB
  • • Typical Return Loss: -55 dB
  • • Buffer Material: PVC
  • • Buffer OD: 900 µm
  • • Jacket Material: PVC (OFNR riser-rated)
  • • Jacket OD: 1.8 mm
  • • Installation Tensile Load: 100 N (445 lbs)
  • • Long-Term Tensile Load: 50 N (222 lbs)
  • • Maximum Tensile Load: 100 N/cm
  • • Installation (Loaded) Minimum Bend Radius: 5.0cm (1.97in)
  • • Long-Term (Unloaded) Minimum Bend Radius: 3.0cm (1.2in)
  • • Crush Resistance: 750 N/cm
  • • Impact Resistance: 1,000 cycles
  • • Flex Resistance: 5,000 cycles
  • • Attenuation at 1550 nm: 0.25 dB/km
  • • Attenuation at 1310 nm: 0.35 dB/km
  • • Operating Temperature: -20°C to +70°C

Ordering Information

o i sm

Download

Download

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets, Via any of these 3 method.

CONTACT US: +65 61003375

EMAIL: sup

CUSTOMER PORTAL

 

 

 

 

How to choose optical fiber patch cord?

 

The Optial Fiber Patch Cord is available for any kind of configurations you need.

ordering

Take me to choose a connector!

Transceiver-Overview!